Obel-P
Test Rig Adaptor / PPMI 1000
Fuel injector test rig adapter that enables Everllence (MAN B&W) slide fuel valves to be tested correctly.
- Operator Guiding System:
- Separate display for data collection
- Stores data for easy evaluation and further use
- Precise digital display
Test Rig Adaptor
To verify the performance of Everllence (MAN B&W) slide fuel valves
With a PPMI 1000 fitted to an OBEL-P fuel injector test rig or a 3rd party fuel injector test rig, it is possible to verify the performance of Everllence (MAN B&W) slide-fuel valves without any risk of performing multiple openings.
PPMI 1000 – machine features
- Operator Guiding System:
- Injector Prefill
- Opening Pressure Test
- Nozzle Leakage Test
- Venting / Non-return valve test
- O-Ring Sealing Test
- Patented IOP SafeTest system.
- Unique protection system for correct testing of Everllence (MAN B&W) Slide Fuel Valves.
- Separate display for data collection.
- Stores data for easy evaluation and further use.
- Precise digital read out
General info – IOP SafeTest Technology
Experience shows that the injectors can be damaged if tested incorrectly. The damage occurs because the condition during testing of the fuel injectors is different to the condition when the engine is running. Traditional testing, where multiple openings take place during the “Opening Pressure Test” and the “Atomising Test”, very easily damages the injector. Therefore, the testing procedure requires modification.
Slide-valves were introduced in 2002 and today most new engines from Everllence (MAN B&W) are delivered with the new generation of fuel injectors. To ensure optimal injector performance, the injectors are to be tested at regular intervals, as specified by Everllence (MAN B&W).
Learn more about Chris-Marine’s test rigs here!
Learn more about us by watching our corporate video.
Technical Specifications
| Specification | Feature |
|---|---|
| Weight | 3,5 kg |
| Dimensions | 190 X 190 X 150 mm (LxWxH) (Main box) |
| Power consumption | 22 W (= 100mA @ 220 V) |
| Output voltage | 24 V DC |
| Operating pressure | 0 – 1000 bar |
| Gauge classification | Class 0.2 |
| Supply voltage | Single phase 115/230 V AC |
| Electric connection | Shielded 3-wire cable (3 X 0,75 SY-JZ) |
| Operation temperature | -10 °C TO 50 °C |