Obel-P
Digital Reference Pressure Indicator / CAL GAUGE
High-precision instrument for verification and calibration of onboard and workshop gauges.
- Pressure range: 0–2500 bar
- Accuracy: ±0.2 % FS
- Unit selector (bar/psi/MPa etc.)
- Set ”reference zero” during operation
- Auto power off
- CEJN 116 or 125 series coupling at outlet
- Microprocessor digital pressure gauge with internal battery
- Optional coupling adapter kit available
Digital Reference Pressure Indicator
High-precision reference pressure indicator for reliable and accurate verification
Chris-Marine’s digital reference pressure indicator, Obel-P Cal Gauge, offers reliable and accurate verification and calibration of onboard and workshop gauges. The Obel-P Cal Gauge is not only highly accurate (class 0.1), but it also features an easy-to-use digital display, enabling quick verification. In addition, it is light-weight and easy to transport.
Features of Obel-P Cal Gauge
- Pressure range: 0-2500 bar
- Very high accuracy: class 0.1
- Unit selector: bar/psi/MPa
- Setting of reference zero: yes
- Auto power off
- Included adaptors: CEJN 116 or 125 series coupling at outlet
- Optional extras: Adaptors for different connectors/couplings
- Versatile: Can also be used as a stand-alone gauge for pressure measurement.
Why choose a digital reference pressure indicator over an analogue one?
A digital display is easier to read and the user can thereby distinguish very small differences that would be impossible to discover with an analogue gauge.
Technical Specifications
| Specification | Feature |
|---|---|
| Weight | 0.9 kg |
| Pressure range | 0-2500 bar |
| Classification | GAUGE: DIGITAL CLASS 0.1 (+/- 2.5 bar) |
| Units | bar / PSI / MPa |
| Setting of reference zero | Yes |
| Logging of peak/max pressure | Logging of peak/max pressure |
| Power source | 4 x 1.5 V AA Batteries (8000+ Hours of operation) |
| Display dimensions | 20 x 60 mm |
| Unit dimensions (LxWxH mm) | 90 x 120 x 60 |
| Liquid connection | G1/2 MALE |
| Included adapters | 1 PCS. CEJN 116 OR 125 SERIES COUPLING |
| Optional extras | Adapters for different connectors/couplings |
For complete technical specifications, download the product sheet or contact our technical team.
Get in touch
Need help choosing the right configuration?
Our technical team can advise on the correct setup for your engine type and operation.